JULY 2005
SOLICITATION FOR OFFERS
OUTPATIENT CLINIC
SFO NO. V101-183R-xxx-xxx-xx
[INSERT LOCATION OF FACILITY]
Lessor will develop and submit a signage plan for review and approval by the Contracting Officer during
design development. The Lessor will furnish and install interior signs for all rooms, areas, conditions or
features in the facility.
7.13 BUILT-IN WORK:
7.13.1 CASEWORK AND COUNTERTOPS:
Plastic laminate casework and countertops shall be in accordance with the requirements in VA Master
Construction Specifications Sections 06200, Finish Carpentry and Millwork; 12302, Wood Casework; and
12303, Countertops and Accessories. Type(s), quantities and locations shall be per Schedule B and as
shown on conceptual plans.
Special counter tops (wood, stainless steel, chemical resistant laminate, or epoxy) shall be provided as
indicated in Schedule B.
7.13.2 COMPUTER WORKSTATIONS AND KEYBOARD TRAYS:
Computer keyboard tray shall be provided at each sit down height and standing height knee space in
casework and at each Radiology room control station countertop.
7.13.3 LOCKERS AND SHELVING:
Lockers and shelving shall be in accordance with the requirements in VA Master Construction
Specifications. Type(s), quantities and locations shall be per Schedule B and as shown on conceptual
plans.
7.14 PLUMBING FIXTURES, TOILETS AND BATHS:
7.14.1 TOILETS:
Toilet partitions shall be in accordance with the requirements in VA Master Construction Specification
10162, Toilet Partitions and Urinal Screens. All toilet stall partitions are to be ceiling hung. Use stainless
steel with #4 satin finish for toilet stall partitions, urinal screens, and room entrance screens. Exceptions:
Room entrance screens that double as part of a toilet partition enclosure shall be of typical stud
construction, from floor to ceiling.
Do not use toilet stalls or divider partitions in single-user toilet rooms in which only a lavatory and water
closet are provided.
Provide ceramic tile flooring and ceramic tile wainscots with paint above as listed in Schedule C.
7.14.2 SHOWERS:
Use ceramic tile applied with thinset Portland cement to concrete-fiber reinforced backer board for shower
enclosures and partitions of contiguous areas.
Use non-slip finished ceramic tile floors for showers and contiguous spaces. Depress the structural floor
of patient showers and contiguous spaces in new buildings 3 inches and place a 3 inch removable fill on
the entire floor area. In new buildings, warp finished floors of patient bath rooms toward showers to assure
Part I: Basic Solicitation Requirements Page 153 of 169
Lessor __________ Gov't. __________
__________ of __________ Pages