Department of Veterans Affairs
Program Guide PG-18-14
Office of Facilities Management
Chapter - 286
December 2004
ROOM FINISHES, DOOR AND HARDWARE SCHEDULE
Service - Surgical
ROOM OR SPACE
DOORS
HARDWARE
FLOOR
BASE
WALLS
WAIN
CEILING
DOOR
H.W.NO.
SYMBOL
Dedicated Electrical
WSF
WSF
GWB
GWB
1/2 V
13
Closet (Clean Core
(SC)
OR's)
Automatic Uniform
VCT
RB
GWB
AT
1/2 S
67
Dispensing Room
Locker, Lounge, Toilet, and Shower Facilities (LLTS):
Lounge, Entire
CP
RB
GWB/W
AT
1/2 S-T
1
Surgical Suite Staff
Lounge, Surgeons,
CP
RB
GWB-W
AT
1/2 S-T
1
Residents, and
Students
Lounge, Nurses &
CP
RB
GWB-W
AT
1/2 S-T
1
Other OR Staff
Members
Nourishment Kitchen
VCT
RB
GWB-W
AT
1/2 S-T
23
(Reserved)
Dictation Cubicle
CP
RB
GWB-W
AT
Open
Locker Rooms
VCT
RB
GWB
AT
1/2 S
1
(Male/Female)
CT1
Shower Area
CT
CT
PCP
1/2 S/
1
Male/Female
Open
Ambulatory Surgery Support Space:
Changing Cubicles &
WSF
WSF
GWB
GWB
1/2 S
1
Patient Lockers
(SC)
Wheelchair Toilet
CT
CT
GWB
CT
GWB
1/2 S
14
(Male/Female)
(SC)
4'0"
Post Operative
WSF
WSF
GWB
GWB
1/2 W-T
67
Recovery Lounge
(SC)
Cystoscopy Suite and Cystoscopy Suite Support (Septic Surgery)1:
GWB
15 V-V
104
Cystoscopy Room
WSF
WSF
GWB
(SC)2
15 QQ-V
109
1
CT on concrete backer board.
2
See Architectural Design Manual PG-18-10, Chapter 5, for lead lining in X-Ray Rooms.
128