JULY 2005
SOLICITATION FOR OFFERS
OUTPATIENT CLINIC
SFO NO. V101-183R-xxx-xxx-xx
[INSERT LOCATION OF FACILITY]
5.2.7
ENTRANCES TO BUILDING:
Analyze special requirements for entrances to buildings based on the requirements in the Architectural
Criteria. Particular reference is made to complying with vertical clearances of buildings and canopies over
roadways and vehicular access areas//, and snow melting requirements at specific entrances//.
Provide access for ambulance entry.
5.2.8
TRUCK DOCK DESIGN:
Design adequate space for truck maneuverability and parking of facility equipment, including trash
dumpsters.
Editing Note: Determine number of spaces required in
accordance with VA Parking Guide. Insert required
number of spaces here and in Paragraph 1.11.
5.2.9
PARKING FACILITIES:
Develop sufficient new parking so that the total number of facility spaces will be the greater of [____]
spaces, or as required by local codes.
Design parking facilities to accommodate people with disabilities. The required minimum number of
accessible parking spaces shall comply with Paragraph 1.11.1. Locate these parking spaces convenient
to an entrance accessible by physically disabled people.
Parking at angles other than 90 degrees may be used only when justifiable. Contracting Officer approval
is required for deviation. Acceptable dimensions for 90 degrees parking angle are as follows.
Minimum Bay
Minimum Stall
Width
Width
If cars overhang curbs on
60' "
-0
8' "
-6
both sides
59' "
-0
8' "
-9
58' "
-0
9' "
-0
If cars overhang curbs on one
62' "
-6
8' "
-6
side
61' "
-6
8' "
-9
60' "
-6
9' "
-0
If cars will not overhang either
65' "
-0
8' "
-6
curb or will be parked in the
64' "
-0
8' "
-9
center bumper to bumper
63' "
-0
9' "
-0
Accessible Spaces
8'-0" w/ 5'-0" access aisle
on both sides
Accessible Van Spaces
8'-0" w/ 8'-0" access aisle
Patient and Visitor spaces shall be 9'-0" minimum width, unless the Contracting Officer approves deviation.
Minimum vertical clearance at Accessible Passenger Loading Zones and Accessible Van Spaces shall be
114 inches. Minimum vertical clearance at other Accessible Spaces shall be 98 inches.
Part I: Basic Solicitation Requirements Page 64 of 169
Lessor __________ Gov't. __________
__________ of __________ Pages