JULY 2005
SOLICITATION FOR OFFERS
OUTPATIENT CLINIC
SFO NO. V101-183R-xxx-xxx-xx
[INSERT LOCATION OF FACILITY]
4.9.4(5)
34" handrail height (not a range of heights)
4.10
Minimum passenger elevator door and platform
sizes, double handrails
4.13
Minimum clear opening 2'-10"
4.17
Toilet Stalls: minimum accessible stall size; grab
bars required in all stalls (not just accessible stalls)
4.21
Patient shower stalls: minimum stall dimensions;
horizontal plus vertical grab bars required
4.22
Minimum width of toilet room entrance doors, 36"
5.0
Cafeterias: knee clearance dimension, for minimum
5-percent of tables; cutlery and supply height
4.7 OSHA REQUIREMENTS:
The Lessor agrees to comply with all Occupational Safety and Health Administration (OSHA) Safety and
Health Standards located in 29 CFR.
The guarding of openings and holes in floors and walls must comply with 29 CFR 1910.23.
The design and construction of fixed stairs for use in other than fire exits must comply with 29 CFR
1910.24.
The design and construction of fixed ladders must comply with 29 CFR 1910.27 or must be clearly marked
or secured to prevent Government employee use.
Physical hazards must be color-coded according to 29 CFR 1910.144 and, where applicable, identified by
signs according to 29 CFR 1910.145.
Where Government employees are exposed to machinery provided by the Lessor, the Lessor must guard
the machinery according to 29 CFR 1910.212.
All tools and equipment provided by the Lessor for Government use must comply with applicable
standards of 29 CFR 1910.
If the Lessor finds it necessary to bring flammable/combustible liquids onto the premises, the provisions of
29 CFR 1910.106 shall govern the handling, use and storage of same.
When work is performed on the building' electrical system, the Lessor shall ensure compliance with the
s
provisions of 29 CFR 1910, Subpart S, where it is obvious that VA employees, beneficiaries or visitors may
be in close proximity to the area where electrical hazards may be present.
Construction, repair, and alteration work done for/by the Lessor shall comply with the current edition of the
OSHA Safety and Health Standards for Construction Industry, 29 CFR 1926, and applicable portions of 29
CFR 1910.
Part I: Basic Solicitation Requirements Page 60 of 169
Lessor __________ Gov't. __________
__________ of __________ Pages