Support Facilities
Small Field Station- Total conference room and multipurpose training room
space allotted is 15 square feet per FTE on station. Stations smaller than 50
FTE should use 50 FTE to compute this space allocation.
Central Meeting Room - will accommodate 50% of the station's FTE, allowing
15 square feet per FTE.
Director's Conference Room - will be adjacent to the Director's suite. A
standard of 375 square feet or 34.84 square meters will be used for this
purpose.
Additional Training Rooms - All remaining meeting room space, after allowing
for the Director's conference room and central meeting room, will be utilized
as multipurpose training/meeting rooms. These rooms should be spaced
throughout the station.
Medium Field Station Total conference room and multipurpose training room
-
space allotted is 15 square feet per FTE on station.
Central Meeting Room - will accommodate 50% of a station's FTE, allowing
15 square feet per FTE.
Director's Conference Room - will be adjacent to the Director's suite. A
standard of 375 square feet or 34.84 square meters will be used for this
purpose.
Additional Training Rooms - All remaining meeting room space, after allowing
for the Director's conference room and central meeting room, will be utilized
as multipurpose training rooms. These rooms should be spaced throughout
the station.
Large Field Station- Total conference room and multipurpose training room
space allotted is 15 square feet per FTE on station up to a maximum of 6,000
square feet per station.
Central Meeting Room - will accommodate 50% of a station's
FTE up to a
maximum 2,250 square feet, allowing 15 square feet per FTE.
Director's Conference Room - will be adjacent to the Director's suite. This
conference room will be 375 square feet or 34.84 square meters.
Additional Training Rooms - All remaining meeting room space, after allowing
for the Director's conference room and central meeting room, will be utilized
as multipurpose training rooms. These rooms should be placed throughout
the station.
Page 2-28
VBA Design Guide