JULY 05
SOLICITATION FOR OFFERS
OUTPATIENT CLINIC
SFO NO. V101-183R-xxx-xxx-xx
[INSERT LOCATION OF FACILITY]
9. VA Satellite TV System:
Provide cabling, outlets, and roof support for VA satellite TV system for reception of VA internal programming. VA shall
provide satellite dish for Lessor installation. The VA shall furnish and install system equipment. Provide coaxial cable,
Belden 7731A, from TV outlets in Classroom and Conference Room to Telephone Equipment Room. Cable from each
room shall be installed to center of Telephone Equipment Room above ceiling with thirty (30) LF of excess cable. Cables
shall be tagged to identify room that cable serves. Provide coaxial cable from Telephone Equipment Room to Satellite
Dish location on roof (250 LF). Provide roof support for satellite dish and means of anchoring satellite dish to roof.
Instalation of VA Satellite TV System with:
2
Outlets
||content||
.00 each outlet.
Roof Support
Anchoring
Coaxial cable to satellite dish
through roof penetration (250 LF)
Satellite dish installation
10. Electronic Access or Door Control System:
Provide complete, operational electronic card //keypad// access //and door control// system. All access
control system products shall be furnished and installed by the same company. Primary Access Control
Equipment shall be manufactured by //Continental//. All equipment shall be the manufacturers current.
Provide //100// //[__]// additional Cards. Provide the following components as necessary for the Access
Control System (see door and hardware type in Schedule C for locations):
Host Computer System shall be located at the //Information Desk// //Security Center// and be used to
program Data, Store Date, Monitor System Conditions, and Generate Reports. The Host Computer
system shall include CPU, Ram Memory, Disk Drives, Color Monitor, Keyboard, Mouse, Operating and
Application Software. Reports shall be printed on the Event and Report Printer located next to the Host
Computer.
Communications Adapters shall be //BB IC485A as manufactured by Black Box Corporation// and shall
provide for Data communications between the Host Computer and the //ApC// Door Controller.
Door Controllers shall provide Access Control for up to eight (8) doors locations and shall provide
Security during Loss of power , and loss of communications with the host computer , store up to 50,000
cards, 1000+ access codes, and buffer up to 15,000 transactions.
Controller UPS Power Supply shall provide Back-up Power to the //ApC// Controller, and Lock Power for
up to eight (8) locks at Amp each. In addition the //AS0063// shall charge //two (2) Sealed Lead Acid
(SLA) Batteries, 12V,24Ah, Yuasa Model NP24-12//.
Card Reader //HID PROXPRO// shall read the Access Card and send the data to the Controller to
determine if the card presented is valid or invalid for the door near its location.
Auxiliary Relay Board ARM shall be mounted near each door having a Card Reader and provide for
output control for the operation of the locking and unlocking of the door.
Exit sensor: //Detection Systems, Inc., Model DS151l//.
UPS Power Supply: //Best 600VA,// shall provide for battery back-up to the host computer for a
minimum of ten (10) minutes. The UPS shall provide for filtering of Power during Transients, and Brown
outs.
Door Switches shall be //Sentrol Model 1076C-W for Wood, Aluminum, or Hollow Metal Doors, and
Part III Special Requirements--Schedule B--Page 8 of 17