SOLICITATION FOR OFFERS
OUTPATIENT CLINIC
SFO NO. V101-183R-xxx-xxx-xx
[INSERT LOCATION OF FACILITY]
Editing Note: include the following paragraph only if
office space is not available for the RE at a nearby VA
facility. Use 720 sf office for projects up to 120,000
NUSF. Match quantities of furnishings and equipment
to office size required. If Paragraph not used, note as
"Reserved."
1.19 //RESIDENT ENGINEERS OFFICE SPACE// //RESERVED//:
The Lessor shall provide a temporary field office, furniture, and two-inch deep gravel-surfaced parking
area for use of the Resident Engineer. Office and furniture shall be new or in "like new" condition.
1.19.1 TEMPORARY FIELD OFFICE:
The field office shall provide not less than // 720 gross square feet // 1440 gross square feet // of floor area
in one unit. Installation of the office shall meet all local codes.
Provide office with two, three foot wide exterior doors, including hardware and OSHA approved platform
and stairs leading to grade. A stainless steel lock guard shall be provided over deadbolts on exterior at
each door.
Enclose the entire perimeter of the office from the floor to the ground and finish to match exterior. Provide
R7 insulation and seal tight to ground with a painted 3/4 inch exterior grade plywood skirt.
Exterior finishes shall be manufacturer' standards.
s
Provide floor, wall, and roof with not less than R5 insulation.
Interior finishes shall consist of resilient flooring, plywood paneling or painted wallboard on walls, and
acoustical tile ceilings. Interior doors may be either painted or stained.
Interior shall be subdivided with full height partitions to provide // one office, // two offices, // one sample
room, // one toilet // two separate toilets //. Provide each space with three foot wide door with master keyed
locks. Section off an area with a low partition and counter for the secretary' desk // s // .
s
Provide 2-1/2 feet wide by 3 feet high operable windows; two in each room (none required in sample
room), except provide only one 2 foot high window with frosted glass in toilet room(s). Provide steel mesh
over all glass in doors and windows. The windows shall have mini-blinds.
Provide sufficient fluorescent lighting in each room to deliver 70 foot-candles of light at desktop height
without the aid of daylight. Provide one light switch in each room.
Provide one duplex receptacle in each wall of each room. If a wall is 10 feet long or more, provide two
receptacles for each 10 feet, or portion thereof, of wall. Provide two duplex receptacles in low partition at
secretary' desk.
s
1.19.2 UTILITIES AND SERVICES:
The Lessor shall provide the following:
Electricity, hot and cold water, and necessary utility services (except telephone).