Department of Veterans Affairs
Program Guide PG-18-14
Office of Facilities Management
Chapter - 270
December 2004
ROOM FINISHES, DOOR AND HARDWARE SCHEDULE
Service Physical Medicine and Rehabilitation
ROOM OR SPACE
DOORS
HARDWARE
FLOOR
BASE
WALLS
WAIN
CEILING
DOOR
H.W.NO.
SYMBOL
Female Wheelchair
CT
CT
GWB
CT
AT
1/2 S
14
Toilet
4'0"
Evaluation Area
VCT
RB
GWB
AT
1/2 U-T
53
Patient Rest Area
VCT
RB
GWB
AT
1/2 U-T
53
Incentive Therapy:
Clinic Office
VCT/CP
RB
GWB
AT
3/4 S-T
23
Assignment Area
VCT
RB
GWB
AT
1/2 V-T
52
Tool Area
VCT
RB
GWB
AT
13/14 S
26
GWB1
Showers, Lavatory, and
CT
CT
CT
AT (SP)
1/2 S
1
Watercloset
4'0"
Cardiopulmonary Rehab. Center Work Evaluation Program:
Administration Offices
CP
RB
GWB
AT
3/4 S-T
23
Evaluation Clinic
VCT
RB
GWB
AT
1/2 V-T
53
Equipment Storage
VCT
RB
GWB
AT
1/2 S
34
Basic Clinic
VCT
RB
GWB
AT
1/2 V-T
53
1/2 V-T2
Therapeutic Pool
CT
CT
CT
PCP
53
Dressing, Showers, and
CT
CT
CT
PCP
1/2 S
1
Toilet Area
Clean/Soiled Towels
CT
CT
CT
PCP
13/14 T
31
and Suits
1263
Corridor
VCT
RB
GWB
AT
1/2 VV-T
ADO
1
Full height CT at tub/shower on concrete backboard with PL ceiling.
2
Provide X door if VAMC includes SCI unit.
3
See Section II, "Doors and Hardware".
100