Department of Veterans Affairs
Program Guide PG-18-14
Office of Facilities Management
Chapter - 270
December 2004
ROOM FINISHES, DOOR AND HARDWARE SCHEDULE
Service Physical Medicine and Rehabilitation
ROOM OR SPACE
DOORS
HARDWARE
FLOOR
BASE
WALLS
WAIN
CEILING
DOOR
H.W.NO.
SYMBOL
Patient Project
See Chapter 100
Storage
Basic Clinic:
1/2 V-T1
Treatment Area
VCT
RB
GWB
AT
53
Storage
VCT
RB
GWB
AT
1/2 U-W
13
or 11/ 12
Activities of Daily Living Evaluation and Training Center:
Kitchen
VCT
RB
GWB
AT
Bedroom
VCT/CP
RB
GWB/W
AT
1/2 S
18
Bathroom
CT
CT
GWB
CT
GWB
1/2 S
18
4'0"
Vocational Rehab. Therapy:
Clinic Office
VCT/CP
RB
GWB
AT
3/4 S-T
23
1/2 V-T1
Treatment Clinic
VCT
RB
GWB
AT
53
Equipment Storage
VCT
RB
GWB
AT
1/2 S
34
Educational Therapy:
Clinic Office
VCT/CP
RB
GWB
AT
3/4 S-T
23
1/2 V-T1
Treatment Clinic
VCT
RB
GWB
AT
53
Equipment Storage
VCT
RB
GWB
AT
1/2 S
34
Driver Training:
Clinic Office
VCT/CP
RB
GWB
AT
3/4 S-T
23
Instruction,
VCT/CP
RB
GWB
AT
1/2 V-T
52
Orientation, and
Simulator Area
Compensated Work Therapy:
Clinic Office
VCT/CP
RB
GWB
AT
3/4 S-T
23
1/2 V-T1
Clinic Work Area
VCT
RB
GWB
AT
52
Storage Area
VCT
RB
GWB
AT
11/12 U-W
13
Male Wheelchair Toilet
CT
CT
GWB
CT
AT
1/2 S
14
4'0"
1
Provide X door if VAMC includes SCI Unit.
99