JULY 05
SOLICITATION FOR OFFERS
OUTPATIENT CLINIC
SFO NO. V101-183R-xxx-xxx-xx
[INSERT LOCATION OF FACILITY]
WD
Wood
WP
Wallcovering Protective (Rigid PVC Sheet)
WSF
Welded Seam Sheet Flooring
Editing Note: Selections should be made by the VA and
Schedule C edited prior to the issue of the SFO.
In Schedule C, where a combination of materials are
separated by the symbol "/", i.e., GWB/CMU, AT/(GWB), etc.,
the designer shall select the appropriate materials from
those listed on the basis of project requirements and cost
and shall detail and specify only the selected materials in the
project documents. The "/" indicate the option of materials
listed. Where a combination of materials separated by the
symbol "-", i.e., GWB-W, etc., indicates an additional material
finish or modification
1.2.2 OTHER REQUIREMENTS
1.2.2.1 SAFETY GLASS
There are three (3) types of safety glass that may be required in Interior Spaces; these are:
Wire Glass ("W") in steel frames shall be used in the following areas:
Observation Windows in fire rated partitions and smoke partitions.
Vision panels in fire rated doors and smoke doors.
Laminated Fire Glass may be substituted for wire glass in fire rated assemblies. Laminated fire
2
glass is preferred for glass over 0.065 m (100 square inches).
Tempered Glass ("T") shall be used in all other Observations Windows and Doors with vision
panels, including side lights.
1.2.2.2 WALL PROTECTION AT DRINKING FOUNTAINS AND LAVATORIES
Provide vinyl wall covering behind Drinking Fountain Alcoves where wallboard or plaster finish occur and
behind lavatories and end walls in examination rooms, treatment rooms, etc. at a minimum 50 inches wide
(or terminating at the nearest inside corner). The vinyl wall covering shall go from base to ceiling.
Editing Note: type WP vinyl wallcovering consists of a solid,
rigid vinyl material without a fabric backing. It is intended for
use as wall protection with or with out bumper rails. Corner
guards are still required. Color and texture of the WP
material can be coordinated with vinyl handrails, bumper
rails, and corner guards. Use materials over 0.035-inch in
high-abuse areas such as service corridors.
1.2.2.3 WALLCOVERING PROTECTIVE (WP), RIGID PVC SHEET
Provide rigid, embossed, impact-resistant protective wallcovering of PVC plastic sheets or roll stock.
Material shall have following minimum properties: Thickness: //0.028 inch// //0.035 inch// //0.060 inch//
//0.080 inch//; Roll Width: 48 inches; or Sheet Size: 48 by 96 inches; Flame/Smoke Ratings: ASTM E 84,
Class A; Flame Spread 0-25; Smoke Developed 0-450. Provide accessories: color matched rigid vinyl
moldings and trim; acrylic latex primer/sealer, and mildew-resistant adhesives and caulk. Materials shall
be cadmium and mercury free.
Part V Schedule C Page 5 of 11
Lessor __________ Gov't. __________
__________ of __________ Pages