June 99
Administration Room Relationships
Visitors enter the building through the "front door" and are greeted in
the office adjacent to the general office. Areas that are open to the public
include the director's office, the General Office and the Multipurpose
Room. A unisex toilet to serve the Administrative staff will also serve the
infrequent public use. The Operations Center is the hub of the office,
containing shared office equipment and files. The staff and volunteers
enter the administration building through the "back door," or employee
entrance, adjacent to the employee parking lot. The lunchroom should be
isolated from public view and can serve as the connector for
Administration and Maintenance "wings". Refer to Section 3, Room
Relationship Diagrams for an example of recommended adjacencies.
Parking
Public parking at the Administration/Maintenance complex should
include a parking pull-off, parallel to the road to accommodate an average
of three (3) cars for cemetery visitors.
VA Design Guide -- National Cemetery Administration
Page 2 -19