SECTION 12347
MOLDED PLASTIC CASEWORK
1.
This section provides inspection and test procedures for molded plastic
casework system including support coils, work surfaces,and utility
modulars.
2.
Symbol
Item Description
Prefixed by "MVL" ........Molded plastic casework system including all
accessories.
3.
INSPECTION AND TEST
A.
Visual Examination:
After installation, all molded plastic casework and
components should be examined for the following defects:
1)
Materials used to construct support components, service modules,
surface components, and storage components of the casework
system is not as specified.
2)
Any component of the casework system not installed as specified.
3)
Countertop and work surface is not specified thickness.
4)
Finish not as specified. Not finished where required. Scratched
or marred.
5)
Any component missing or not type specified.
6)
Casework fastening and anchorage not as specified.
7)
Water faucets not type specified.
8)
Utilities not plumbed in service module as specified.
B.
Certification Compliance Examination:
Certifications, certified test reports,
or listing marks for codes and standards, as applicable, should be
examined and validated as proof of compliance.
1)
Molded plastic casework should conform to the following
standards:
-
National Electrical Manufacturers Association (NEMA)
-
National Fire Protection Association (NFPA)
2)
Conformance to these standards should be evidence by seal,
label, stamp or certified test reports.
12347-1