VA HANDBOOK 7610 (703)
April 1, 1987
Tasks ..............................................................Unloading headstones, etc. from trucks
Users ..............................................................Maintenance Staff
Special Requirements .......................................Concrete dock with ramp - minimum height
1070 mm (42"), minimum width 2440 mm (8')
6. DESIGN CONSIDERATIONS
a. The maintenance and service will be fenced for security purposes and screened from public view. Provide for
fire and security alarm system and security lighting of areas immediately around the building.
b. Toilet and shower facilities assigned to females should be so arranged as to be usable by males when no
females are assigned to the staff. A single entry to both spaces is recommended.
c. The Vehicle and Equipment Maintenance Area should have minimum depth of 9145 mm (30') and be provided
with a system to remove vehicle exhaust.
d. Parts and Tools Storage should be easily accessible from the Foreman's office and the Vehicle and
Equipment Maintenance Area.
e. In Parts and Tools Storage the volume of space over 3135 mm (7') high should be utilized to the greatest
extend possible mezzanine storage.
f. Insecticide Storage requires and exhaust fan.
g. Workshops require a positive ventilation system.
h. Vehicle and Equipment Storage - Definitions.
(1) Enclosed - structure will have a roof and be enclosed on all 4 sides.
(2) Sheltered - structure will have a roof and be enclosed on 3 sides.
(a) Exception - structure will have a roof and be open on all sides in geographical location where climate
permits.
(3) Paved - no structure.
703-10